{"product":{"total":4,"offset":0,"limit":4,"data":[{"path":"/products/microplate-readers/multi-mode-readers/spectramax-m2-m2e-readers","identifier":"SpectraMax M2/M2e Multi-Mode Microplate Reader","title":"M2/M2e Multi-Mode Microplate Reader","categories":"general"},{"path":"/products/microplate-readers/multi-mode-readers/spectramax-m3-multi-mode-microplate-reader","identifier":"SpectraMax M3 Multi-Mode Microplate Reader","title":"M3 Multi-Mode Microplate Reader","categories":"general"},{"path":"/products/microplate-readers/multi-mode-readers/spectramax-m4-reader","identifier":"SpectraMax M4 Multi-Mode Microplate Reader","title":"M4 Multi-Mode Microplate Reader","categories":"general"},{"path":"/products/microplate-readers/multi-mode-readers/spectramax-m5-m5e-readers","identifier":"SpectraMax M5/M5e Multi-Mode Microplate Reader","title":"M5/M5e Multi-Mode Microplate Reader","categories":"general"}],"columns":["path","identifier","title","categories"]},"general":{"total":5,"offset":0,"limit":5,"data":[{"key":"label","path":"path","name":"Name","identifier":"Identifier","read-modes":"Read modes","wavelength-ranges":"Wavelength ranges","wavelength-selection":"Wavelength selection","absorbance-photometric-accuracylinearity":"Absorbance photometric accuracy/linearity","absorbance-photometric-precisionrepeatability":"Absorbance photometric precision/repeatability","sensitivity-top-read-optimized":"Sensitivity top read optimized","light-sources":"Light source(s)","detectors":"Detector(s)","read-types-endpoint-kinetic-etc":"Read types (endpoint, kinetic, etc)","read-times":"Read times","plate-shaking":"Plate shaking","cuvette-port":"Cuvette port","robotics--automation":"Robotics / automation","plate-types":"Plate type(s)","temperature-control":"Temperature control","dimensions":"Dimensions","validation-tools":"Validation tools"},{"key":"value1","path":"/products/microplate-readers/multi-mode-readers/spectramax-m2-m2e-readers","name":"General specifications","identifier":"SpectraMax M2/M2e Multi-Mode Microplate Reader","read-modes":"Absorbance\nFluorescence (top/bottom read)","wavelength-ranges":"Abs: 200 - 1000 nm\nFL Ex: 250 - 850 nm \nFL Em: 360  - 850 nm (M2)\nFL Em: 250  - 850 nm (M2e)","wavelength-selection":"Monochromator tunable in 1-nm increments","absorbance-photometric-accuracylinearity":"< ±1.0% and ±0.006 OD (0.0-2.0 OD)","absorbance-photometric-precisionrepeatability":"< ±1.0% and ±0.003 OD (0.0-2.0 OD)","sensitivity-top-read-optimized":"FL: 3.0 fmol/well in 200 μL FITC 96 well (15 pM), 3.0 fmol/well in 75 μL FITC 384 well (40 pM)","light-sources":"Xenon flashlamp","detectors":"Silicon photodiode\nPhotomutiplier tube","read-types-endpoint-kinetic-etc":"Endpoint\nKinetic\nSpectrum scan\nWell scan","read-times":"Abs: 17 seconds\nFL: 15 seconds","plate-shaking":"Linear","cuvette-port":"true","robotics--automation":"true","plate-types":"6 - 384 well plates","temperature-control":"true\nAmbient +  4°C to 45°C","dimensions":"H 22 cm x W 58 cm x D 39 cm","validation-tools":"true\nAbsorbance validation plate\nFluorescence validation plate\nSoftMax Pro GxP Software"},{"key":"value2","path":"/products/microplate-readers/multi-mode-readers/spectramax-m3-multi-mode-microplate-reader","name":"General specifications","identifier":"SpectraMax M3 Multi-Mode Microplate Reader","read-modes":"Absorbance\nFluorescence (top/bottom read)\nLuminescence (top/bottom read)","wavelength-ranges":"Abs: 200 - 1000 nm\nFL: 250 - 850 nm\nLumi: 250 - 850 nm","wavelength-selection":"Monochromator tunable in 1-nm increments","absorbance-photometric-accuracylinearity":"< ±1.0% and ±0.006 OD (0.0-2.0 OD)","absorbance-photometric-precisionrepeatability":"< ±1.0% and ±0.003 OD (0.0-2.0 OD)","sensitivity-top-read-optimized":"FL:  1 fmol/well in 200 μL FITC 96 well (< 5 pM), 2 fmol/well in 100 μL FITC 384 well (< 20 pM)\nLumi: < 2 fg/well for firefly luciferase in 96 and 384 well","light-sources":"Xenon flashlamp","detectors":"Silicon photodiode\nPhotomutiplier tube","read-types-endpoint-kinetic-etc":"Endpoint\nKinetic\nSpectrum scan\nWell scan","read-times":"Abs: 17 seconds\nFL: 15 seconds\nLumi: 17 seconds","plate-shaking":"Linear","cuvette-port":"true","robotics--automation":"true","plate-types":"6 - 384 well plates","temperature-control":"true\nAmbient +  2°C to 60°C","dimensions":"H 22 cm x W 58 cm x D 39 cm","validation-tools":"true\nAbsorbance validation plate\nFluorescence validation plate\nLuminescence validation plate\nSoftMax Pro GxP Software"},{"key":"value3","path":"/products/microplate-readers/multi-mode-readers/spectramax-m4-reader","name":"General specifications","identifier":"SpectraMax M4 Multi-Mode Microplate Reader","read-modes":"Absorbance\nFluorescence (top/bottom read)\nLuminescence (top/bottom read)\nTime-Resolved Fluorescence (top/bottom read)","wavelength-ranges":"Abs: 200 - 1000 nm\nFL: 250  - 850 nm \nLumi: 250 - 850 nm\nTRF: 250 - 850 nm","wavelength-selection":"Monochromator tunable in 1-nm increments","absorbance-photometric-accuracylinearity":"< ±1.0% and ±0.006 OD (0.0-2.0 OD)","absorbance-photometric-precisionrepeatability":"< ±1.0% and ±0.003 OD (0.0-2.0 OD)","sensitivity-top-read-optimized":"FL:  1 fmol/well in 200 μL FITC 96 well (< 5 pM), 2 fmol/well in 100 μL FITC 384 well (< 20 pM)\nLumi: < 2 fg/well for firefly luciferase in 96- and 384-well \nTRF: 100 fM europium in 96 or 384 well","light-sources":"Xenon flashlamp","detectors":"Silicon photodiode\nPhotomutiplier tube","read-types-endpoint-kinetic-etc":"Endpoint\nKinetic\nSpectrum scan\nWell scan","read-times":"Abs: 17 seconds\nFL: 15 seconds\nLumi: 17 seconds\nTRF: 15 seconds","plate-shaking":"Linear","cuvette-port":"true","robotics--automation":"true","plate-types":"6 - 384 well plates","temperature-control":"true\nAmbient +  2°C to 60°C","dimensions":"H 22 cm x W 58 cm x D 39 cm","validation-tools":"true\nAbsorbance validation plate\nFluorescence validation plate\nLuminescence validation plate\nSoftMax Pro GxP Software"},{"key":"value4","path":"/products/microplate-readers/multi-mode-readers/spectramax-m5-m5e-readers","name":"General specifications","identifier":"SpectraMax M5/M5e Multi-Mode Microplate Reader","read-modes":"Absorbance\nFluorescence (top/bottom read)\nLuminescence (top/bottom read)\nTime-Resolved Fluorescence (top/bottom read)\nFluorescence Polarization (top read)\nHTRF (top/bottom read)","wavelength-ranges":"Abs: 200 - 1000 nm\nFL: 250  - 850 nm \nLumi: 250 - 850 nm\nTRF: 250 - 850 nm\nFP: 300 - 750 nm","wavelength-selection":"Monochromator tunable in 1-nm increments","absorbance-photometric-accuracylinearity":"< ±1.0% and ±0.006 OD (0.0-2.0 OD)","absorbance-photometric-precisionrepeatability":"< ±1.0% and ±0.003 OD (0.0-2.0 OD)","sensitivity-top-read-optimized":"FL:  1 fmol/well in 200 μL FITC 96 well (< 5 pM), 2 fmol/well in 100 μL FITC 384 well (< 20 pM)\nLumi: < 2 fg/well for firefly luciferase in 96 and 384 well\nTRF: 100 fM europium in 96 and 384 well\nFP: < 5 mP standard deviation at 1 nM fluorescein in 96 and 384 well","light-sources":"Xenon flashlamp","detectors":"Silicon photodiode\nPhotomutiplier tube","read-types-endpoint-kinetic-etc":"Endpoint\nKinetic\nSpectrum scan\nWell scan","read-times":"Abs: 17 seconds\nFL: 15 seconds\nLumi: 17 seconds\nTRF: 15 seconds\nFP: 44 seconds","plate-shaking":"Linear","cuvette-port":"true","robotics--automation":"true","plate-types":"6 - 384 well plates","temperature-control":"true\nAmbient +  2°C to 60°C","dimensions":"H 22 cm x W 58 cm x D 39 cm","validation-tools":"true\nAbsorbance validation plate\nFluorescence validation plate\nLuminescence validation plate\nSoftMax Pro GxP Software"}],"columns":["key","path","name","identifier","read-modes","wavelength-ranges","wavelength-selection","absorbance-photometric-accuracylinearity","absorbance-photometric-precisionrepeatability","sensitivity-top-read-optimized","light-sources","detectors","read-types-endpoint-kinetic-etc","read-times","plate-shaking","cuvette-port","robotics--automation","plate-types","temperature-control","dimensions","validation-tools"]},":version":3,":names":["product","general"],":type":"multi-sheet"}