{"product":{"total":2,"offset":0,"limit":2,"data":[{"path":"/products/clone-screening/microbial-screening/qpix-400-series-microbial-colony-pickers","identifier":"QPix 420 System","title":"QPix 420 System","categories":"imaging,instrumentation,software,regulatory,compressedAir"},{"path":"/products/clone-screening/microbial-screening/qpix-400-series-microbial-colony-pickers","identifier":"QPix 450/460 Systems","title":"QPix 450/460 Systems","categories":"imaging,instrumentation,software,regulatory,compressedAir"}],"columns":["path","identifier","title","categories"]},"instrumentation":{"total":3,"offset":0,"limit":3,"data":[{"key":"label","path":"path","identifier":"Identifier","name":"Name","spreading-capability-qpix-460-system-only":"Spreading capability (QPix 460 System only)","destination-plate-capacity":"Destination plate capacity","source-plate-capacity":"Source plate capacity","dimensions":"Dimensions","picking-destination-plate-type":"Picking destination plate type","picking-height":"Picking height","picking-head":"Picking head","pin-drying":"Pin drying","wash-bath":"Wash bath","picking-capacity":"Picking capacity","picking-pin-types":"Picking pin types"},{"key":"value1","path":"/products/clone-screening/microbial-screening/qpix-400-series-microbial-colony-pickers","identifier":"QPix 420 System","name":"Instrumentation","spreading-capability-qpix-460-system-only":"","destination-plate-capacity":"QPix 420 System: Picking: 12 plates; replicating and re-arraying, maximum of 20 plate positions","source-plate-capacity":"QPix 420 System: Without manual intervention: 1 x 15 cm petri dish; 5 x 9 cm petri dishes; 2 x OmniTrays; 1 x 22 cm QTrays","dimensions":"QPix 420 System (without table): 1460 mm (width) x 770 mm (depth) x 750 mm (height)","picking-destination-plate-type":"Various, 24, 48, 96 or 384-well, including deep well","picking-height":"Various, 24, 48, 96 or 384-well, including deep well","picking-head":"Fully pneumatic, 96 pin picking head. Interchangeable heads for other applications","pin-drying":"Proprietary halogen pin drying station","wash-bath":"3 x static wash baths","picking-capacity":"3000 colonies per hour in white light, 2000 colonies per hour in fluorescent light","picking-pin-types":"Range of organism-specific pins"},{"key":"value2","path":"/products/clone-screening/microbial-screening/qpix-400-series-microbial-colony-pickers","identifier":"QPix 450/460 Systems","name":"Instrumentation","spreading-capability-qpix-460-system-only":"Sampling and spreading source plate: 1 x 96-well (30 minutes for 96 samples). Aspiration volume 10-130 µL. Destination plate: 2 x 22 cm 48 region QTrays. Samples spread from pre-set or customizable pattern","destination-plate-capacity":"QPix 460 System: Up to 140 low profile plates, 70 per stacker lane, maximum 2 stackers","source-plate-capacity":"QPix 450/460 System: Without manual intervention: 2 x 15 cm petri dish; 10 x 9 cm petri dishes; 4 x OmniTrays; 2 x 22 cm QTrays","dimensions":"QPix 450/460 System: 2200 mm (width, excluding monitor arm) x 800 mm (depth) x 2140 mm (height on table)","picking-destination-plate-type":"Integrated ultrasonic agar height sensor to set agar height per plate for accurate picking","picking-height":"Integrated ultrasonic agar height sensor to set agar height per plate for accurate picking","picking-head":"Fully pneumatic, 96 pin picking head. Interchangeable heads for other applications","pin-drying":"Proprietary halogen pin drying station","wash-bath":"3 x static wash baths","picking-capacity":"3000 colonies per hour in white light, 2000 colonies per hour in fluorescent light","picking-pin-types":"Range of organism-specific pins"}],"columns":["key","path","identifier","name","spreading-capability-qpix-460-system-only","destination-plate-capacity","source-plate-capacity","dimensions","picking-destination-plate-type","picking-height","picking-head","pin-drying","wash-bath","picking-capacity","picking-pin-types"]},"regulatory":{"total":3,"offset":0,"limit":3,"data":[{"key":"label","path":"path","identifier":"Identifier","name":"Name","compliance":"Compliance","quality":"Quality"},{"key":"value1","path":"/products/clone-screening/microbial-screening/qpix-400-series-microbial-colony-pickers","identifier":"QPix 420 System","name":"Regulatory Approval","compliance":"CE","quality":"ISO9001:2008 certified"},{"key":"value2","path":"/products/clone-screening/microbial-screening/qpix-400-series-microbial-colony-pickers","identifier":"QPix 450/460 Systems","name":"Regulatory Approval","compliance":"CE","quality":"ISO9001:2008 certified"}],"columns":["key","path","identifier","name","compliance","quality"]},"imaging":{"total":3,"offset":0,"limit":3,"data":[{"key":"label","path":"path","identifier":"Identifier","name":"Name","camera-white-light-only-system":"Camera (white light only system)","camera-white-light-and-fluorescence-system":"Camera (white light and fluorescence system)","fluorescent-imaging-optional":"Fluorescent imaging (optional)","colony-statistics":"Colony statistics","tracking":"Tracking"},{"key":"value1","path":"/products/clone-screening/microbial-screening/qpix-400-series-microbial-colony-pickers","identifier":"QPix 420 System","name":"Imaging","camera-white-light-only-system":"CCD Camera, image resolution: 22 pixels /mm. Field of view: 62 x 46 mm","camera-white-light-and-fluorescence-system":"CCD Camera, image resolution 22 pixels /mm. Field of view: 32 x 24 mm","fluorescent-imaging-optional":"Epifluorescence illumination, five standard wavelengths included: \nEx /Em: 377 /447 nm for DAPI /Hoechst \nEx /Em: 457 /536 nm for FITC /GFP \nEx /Em: 531 /593 nm for Cy3 /DS Red \nEx /Em: 628 /692 nm for Cy5 \nEx /Em: 531 /624 nm for Rhodamine /Texas Red","colony-statistics":"Colonies selectable based on size, proximity, roundness, fluorescence intensity. Selection performed on whole tray image","tracking":"1 x barcode reader for tracking of source and destination plates. Data tracked through all applications for plates with same I.D."},{"key":"value2","path":"/products/clone-screening/microbial-screening/qpix-400-series-microbial-colony-pickers","identifier":"QPix 450/460 Systems","name":"Imaging","camera-white-light-only-system":"CCD Camera, image resolution: 22 pixels /mm. Field of view: 62 x 46 mm","camera-white-light-and-fluorescence-system":"CCD Camera, image resolution 22 pixels /mm. Field of view: 32 x 24 mm","fluorescent-imaging-optional":"Epifluorescence illumination, five standard wavelengths included: \nEx /Em: 377 /447 nm for DAPI /Hoechst \nEx /Em: 457 /536 nm for FITC /GFP \nEx /Em: 531 /593 nm for Cy3 /DS Red \nEx /Em: 628 /692 nm for Cy5 \nEx /Em: 531 /624 nm for Rhodamine /Texas Red","colony-statistics":"Colonies selectable based on size, proximity, roundness, fluorescence intensity. Selection performed on whole tray image","tracking":"1 x barcode reader for tracking of source and destination plates. Data tracked through all applications for plates with same I.D."}],"columns":["key","path","identifier","name","camera-white-light-only-system","camera-white-light-and-fluorescence-system","fluorescent-imaging-optional","colony-statistics","tracking"]},"software":{"total":3,"offset":0,"limit":3,"data":[{"key":"label","path":"path","identifier":"Identifier","name":"Name","zone-of-inhibition-detection":"Zone of inhibition detection","colorimetric-colony-selection":"Colorimetric colony selection","plate-replication":"Plate replication","re-arraying":"Re-arraying"},{"key":"value1","path":"/products/clone-screening/microbial-screening/qpix-400-series-microbial-colony-pickers","identifier":"QPix 420 System","name":"Software","zone-of-inhibition-detection":"Software license","colorimetric-colony-selection":"Software license and filters","plate-replication":"Software license and additional head","re-arraying":"Software license and additional head"},{"key":"value2","path":"/products/clone-screening/microbial-screening/qpix-400-series-microbial-colony-pickers","identifier":"QPix 450/460 Systems","name":"Software","zone-of-inhibition-detection":"Software license","colorimetric-colony-selection":"Software license and filters","plate-replication":"Software license and additional head","re-arraying":"Software license and additional head"}],"columns":["key","path","identifier","name","zone-of-inhibition-detection","colorimetric-colony-selection","plate-replication","re-arraying"]},"compressedAir":{"total":3,"offset":0,"limit":3,"data":[{"key":"label","path":"path","identifier":"Identifier","name":"Name","air":"Air","minimum-operating-pressure":"Minimum operating pressure","minimum-operating-volume":"Minimum operating volume"},{"key":"value1","path":"/products/clone-screening/microbial-screening/qpix-400-series-microbial-colony-pickers","identifier":"QPix 420 System","name":"Compressed Air Specifications","air":"Clean, oil-free with sub-micron filtration","minimum-operating-pressure":"6 bar (~90psi)","minimum-operating-volume":"80L/min"},{"key":"value2","path":"/products/clone-screening/microbial-screening/qpix-400-series-microbial-colony-pickers","identifier":"QPix 450/460 Systems","name":"Compressed Air Specifications","air":"Clean, oil-free with sub-micron filtration","minimum-operating-pressure":"6 bar (~90psi)","minimum-operating-volume":"80L/min"}],"columns":["key","path","identifier","name","air","minimum-operating-pressure","minimum-operating-volume"]},":version":3,":names":["product","instrumentation","regulatory","imaging","software","compressedAir"],":type":"multi-sheet"}