{"compressedAir":{"total":3,"offset":0,"limit":3,"data":[{"key":"label","name":"Name","path":"path","identifier":"Identifier","air":"Air","minimum-operating-pressure":"Minimum operating pressure","minimum-operating-volume":"Minimum operating volume"},{"key":"value1","name":"Compressed Air Specifications","path":"/products/clone-screening/mammalian-screening/clonepix-2-mammalian-colony-picker","identifier":"ClonePix 2 Mammalian Colony Picker","air":"Clean, oil-free with sub-micron filtration","minimum-operating-pressure":"6 bar (~90psi)","minimum-operating-volume":"80 L/min"},{"key":"value2","name":"Compressed Air Specifications","path":"/products/clone-screening/mammalian-screening/clonepix-2-mammalian-colony-picker","identifier":"ClonePix 2 Mammalian Colony Picker","air":"Clean, oil-free with sub micron filtration","minimum-operating-pressure":"6 bar ( ~90psi)","minimum-operating-volume":"80 L/min"}],"columns":["key","name","path","identifier","air","minimum-operating-pressure","minimum-operating-volume"]},"product":{"total":2,"offset":0,"limit":2,"data":[{"path":"/products/clone-screening/mammalian-screening/clonepix-2-mammalian-colony-picker","identifier":"ClonePix 2 Mammalian Colony Picker","title":"ClonePix 2 Mammalian Colony Picker","categories":"imaging,instrumentation,compressedAir,regulatory"},{"path":"/products/clone-screening/mammalian-screening/clonepix-2-mammalian-colony-picker","identifier":"ClonePix 2 Mammalian Colony Picker","title":"ClonePix 2 Enhanced for Monoclonality Verification","categories":"imaging,instrumentation,compressedAir,regulatory"}],"columns":["path","identifier","title","categories"]},"imaging":{"total":3,"offset":0,"limit":3,"data":[{"key":"label","name":"Name","identifier":"Identifier","path":"path","software":"Software","white-light-imaging":"White light imaging","fluorescence-imaging":"Fluorescence Imaging","data-tracking":"Data tracking","camera":"Camera","imaging-capture-and-transfer":"Imaging capture and transfer","imaging-speed":"Imaging speed","resolution":"Resolution","z-stack-imaging":"Z-Stack Imaging"},{"key":"value1","name":"Imaging","identifier":"ClonePix 2 Mammalian Colony Picker","path":"/products/clone-screening/mammalian-screening/clonepix-2-mammalian-colony-picker","software":"Dedicated imaging software pre-installed on a high-specification PC, Microsoft Windows 10","white-light-imaging":"Trans-illumination for imaging low contrast colonies such as adherent mono layers or small colonies in suspension\nEpi-illumination for imaging colonies as they are collected","fluorescence-imaging":"Software-controlled switching between up to 5 excitation /emission filter pairs","data-tracking":"Internal barcode reader for source and destination plates enables data tracking for each run","camera":"High-resolution CMOS camera (16-bit) \n  \n0.86X objective","imaging-capture-and-transfer":"USB 1.0","imaging-speed":"6-well microplate: 5 min for 2 wavelengths (single plane, standard conditions)","resolution":"Standard: 28 micron","z-stack-imaging":"No"},{"key":"value2","name":"Imaging","identifier":"ClonePix 2 Mammalian Colony Picker","path":"/products/clone-screening/mammalian-screening/clonepix-2-mammalian-colony-picker","software":"Dedicated imaging software pre-installed on a high-specification PC, Microsoft Windows 10 64-bit","white-light-imaging":"Enhanced optical system capable of resolving single cells. \nTrans-illumination for superior contrast imaging. \nXY drive encoders for accurate image tiling \nCamera z stage control to allow rapid z-stack imaging.","fluorescence-imaging":"Software-controlled switching between up to 5 excitation /emission filter pairs \nLumencor AuraIII light engine excitation source for improved FL excitation","data-tracking":"Internal barcode reader for source and destination plates enables data tracking for each run","camera":"High-resolution CMOS camera,  \nBasler 2048 X 2048-pixel, monochrome, selectable bit depth (8 or 12 bits),  \n \n4X objective","imaging-capture-and-transfer":"USB 3.0","imaging-speed":"Single plane, WL only: <15 minutes/plate \nSingle plane, WL&FL: <35 minutes/plate \nStack Imaging, WL only: <45 minutes/plate* \n*assuming 1000um stack, 33um step size","resolution":"Resolving single cells: 10-18 um diameter","z-stack-imaging":"Yes, day 0 stack imaging to allow capture of single cells \nAnd stack imaging for additional time points"}],"columns":["key","name","identifier","path","software","white-light-imaging","fluorescence-imaging","data-tracking","camera","imaging-capture-and-transfer","imaging-speed","resolution","z-stack-imaging"]},"regulatory":{"total":3,"offset":0,"limit":3,"data":[{"key":"label","name":"Name","identifier":"Identifier","path":"path","compliance":"Compliance","quality":"Quality","monoclonality-report":"Monoclonality Report"},{"key":"value1","name":"Regulatory Approval","identifier":"ClonePix 2 Mammalian Colony Picker","path":"/products/clone-screening/mammalian-screening/clonepix-2-mammalian-colony-picker","compliance":"CE","quality":"ISO9001:2008 certified","monoclonality-report":"No"},{"key":"value2","name":"Regulatory Approval","identifier":"ClonePix 2 Mammalian Colony Picker","path":"/products/clone-screening/mammalian-screening/clonepix-2-mammalian-colony-picker","compliance":"CE","quality":"ISO9001:2008 certified","monoclonality-report":"Yes, correlation of selected colonies on pick day back to day 0 XY location"}],"columns":["key","name","identifier","path","compliance","quality","monoclonality-report"]},"instrumentation":{"total":3,"offset":0,"limit":3,"data":[{"key":"label","name":"Name","path":"path","identifier":"Identifier","containment":"Containment","destination-plate-type":"Destination plate type","source-plate-capacity":"Source plate capacity","destination-plate-capacity":"Destination plate capacity","picking-head":"Picking head","picking-pin-size":"Picking pin size","wash-bath":"Wash bath","picking-system-fluids":"Picking system fluids","pin-drying":"Pin drying","instrument-dimensions":"Instrument dimensions","instrument-weight":"Instrument weight"},{"key":"value1","name":"Instrumentation","path":"/products/clone-screening/mammalian-screening/clonepix-2-mammalian-colony-picker","identifier":"ClonePix 2 Mammalian Colony Picker","containment":"Fully enclosed working environment with Class 100-type, HEPA filtration","destination-plate-type":"PetriWell-96 plate, Costar 96-well plate, Greiner 96-well plate, Nunc 96-well plate, Falcon 96-well plate","source-plate-capacity":"10 plates","destination-plate-capacity":"10 plates","picking-head":"8 x picking pins – each pin independently controlled","picking-pin-size":"Diameter of picking pins is application specific – F1: suspension cells, F2: adherent cells","wash-bath":"Ethanol wash bath, automatically refilled","picking-system-fluids":"5 L sterile water supply, 5L waste bottle","pin-drying":"Proprietary halogen pin drying station","instrument-dimensions":"1010 mm (width) x 900 mm (depth) x 1490 mm (height)","instrument-weight":"350 kg"},{"key":"value2","name":"Instrumentation","path":"/products/clone-screening/mammalian-screening/clonepix-2-mammalian-colony-picker","identifier":"ClonePix 2 Mammalian Colony Picker","containment":"Fully enclosed working environment with Class 100-type, HEPA filtration","destination-plate-type":"Greiner 96-well plate, Corning/Costar 96-well, Corning/Falcon 96-well, Thermo Scientific/Nunc, Thermo Scientific/Matrix 96-well","source-plate-capacity":"10 plates without robotic integration","destination-plate-capacity":"10 plates without robotic integration","picking-head":"8 x picking pins – each pin independently controlled","picking-pin-size":"Application specific – F1: suspension cells (0.4 mm), F2: adherent cells (0.7 mm)","wash-bath":"Ethanol wash bath, automatically refilled","picking-system-fluids":"5L sterile water supply, 5L waste bottle","pin-drying":"Proprietary halogen pin drying station","instrument-dimensions":"1010 mm (width) x 900 mm (depth) x 1490 mm (height)","instrument-weight":"350 kg"}],"columns":["key","name","path","identifier","containment","destination-plate-type","source-plate-capacity","destination-plate-capacity","picking-head","picking-pin-size","wash-bath","picking-system-fluids","pin-drying","instrument-dimensions","instrument-weight"]},":version":3,":names":["compressedAir","product","imaging","regulatory","instrumentation"],":type":"multi-sheet"}