SpectraTest Validation Plates and Recertification

 

The SpectraTest® Validation Plates are valuable tools for verifying that absorbance-, fluorescence-, and luminescence-capable microplate readers are operating correctly for GMP and GLP laboratories.

Annual recertification of your validation plates ensure that they meet specifications and give you confidence in the performance of your instrument.

  • Measure Icon

    Measure absorbance, fluorescence, and luminescence with confidence

    Use photometric accuracy tests to verify how close an absorbance measurement is to the true value, which is traceable to the National Institute of Standards and Technology (NIST) and NMI (National Metrology Institutes).

    Determine the accuracy and repeatability of the wavelength selection with the monochromator, which includes separate tests for excitation and emission.

    Qualify the kinetic noise that measures the stability of the optical system at low and high signals, including separate tests for spikes and drift at low and high levels.

  • Accuracy Icon

    Ensure data accuracy of your reader

    We have the necessary knowledge and equipment to recertify SpectraTest Validation Plates

SpectraTest ABS2 Validation Plate

SpectraTest ABS2 Validation Plate

Features

  • SpectraTest FL1 Fluorescence Validation Plate

    SpectraTest FL1 Fluorescence Validation Plate

    The SpectraTest FL1 plate enables PMT matching to ensure linearity of signal over a greater dynamic range, and RFU (Relative Fluorescence Unit) scaling for optional adjustment of the RFU output.

  • Analysis Icon

    Data Analysis

    Preconfigured protocols in SoftMax® Pro GxP Software automatically generate and analyze data. In addition, compliance tools for FDA 21 CFR Part 11 and EudraLex Annex 11 allow for controlled access to test results with audit trails.

  • SpectraTest ABS2 Validation Plate

    SpectraTest ABS2 Absorbance Validation Plate

    This next generation SpectraTest ABS2 plate measures the sensitivity of the optical system ensuring that it is uncompromised by stray light. The plate includes automated certificate value entry and is compatible with our StakMax® Microplate Handling System.

  • Recertification service

    Recertification service

    • Molecular Devices is ISO 17025 accredited† by American Association of Laboratory Accreditation (A2LA), which requires rigorous outside auditing on a regular basis so that you can be assured of the accuracy of your certificate with respect to NIST and NMI traceable standards
    • Gold Standard and Reference Standard Molecular Devices microplate readers are used for recertification so that your certificate values are traceable
    • If validation plate repair is needed, only factory-approved parts that meet our internal specifications for these plates are used
    • Rapid turnaround time of five business days or less; expedited service is available as needed

     

    View our ISO 17025 certificate of accreditation.

  • SpectraTest LM1 Luminescence Validation Plate

    SpectraTest LM1 Luminescence Validation Plate

    The SpectraTest LM1 plate enables tests for background noise and spikes, crosstalk to measure light from adjacent wells, and checks for left-to-right bias from the left to the right edge of the plate.

Latest Resources

16

Resources of SpectraTest Validation Plates and Recertification

Presentations
Videos & Webinars
SpectraTest ABS2 Validation Plate

SpectraTest ABS2 Validation Plate

GxP compliance solutions for GMP/GLP labs

GxP compliance solutions for GMP/GLP labs

SpectraTest Validation Plates

Product

Part Number

SpectraTest ABS2 Absorbance Validation Plate 0200-6191
SpectraTest FL1 Fluorescence Validation Plate 0200-5060
SpectraTest LM1 Luminescence Validation Plate 0200-6186
Cuvette Absorbance Validation Set 0200-2420
Multi-Mode Validation Plate 0200-7200
Gray replacement validation plate case 5074718

 