CatchPoint cAMP Fluorescent Assay Kit

cAMP Fluorescent Assay Kit's high-affinity reagents are optimized for sensitivity and precision in applications where cAMP levels are low. A single wash step removes unbound material prior to the development step, so the assay is very resistant to interference from colored or fluorescent test compounds. The proprietary Stoplight Red substrate is used to generate a stable fluorescent readout, allowing the assay to be read in as little as 10 minutes or up to 24 hours after substrate addition.

Benefits of CatchPoint cAMP Fluorescent Assay Kit:
 

  • High affinity reagents are optimized for sensitivity when cAMP levels are low, ensuring results when other assays fail.
  • Robust format resists interference from colored or fluorescent compounds, improving reliability of results.
  • Rapid signal development (< 10 min) and no termination step give users a flexible read time that is compatible with automation and high-throughput screening.
  • Quantitative method allows accurate determination of cAMP in samples.

Data of CatchPoint cAMP Fluorescent Assay Kit

  • cAMP calibration curve

    cAMP Calibration Curve

    The calibration curve for the CatchPoint® cAMP Assay Kit was generated on a SpectraMax® M5 Multi-Mode Microplate Reader. Data were taken 24 hours after addition of Stoplight Red substrate. The EC50of the cAMP calibration curve was 5.1 nM.

  • Forskolin Dose Response in HEK293 Cells

    10,000 cells were stimulated in a volume of 20 μL for 15 minutes, then lysed and analyzed using the CatchPoint cAMP Fluorescent Assay Kit. Data were generated on a SpectraMax M5 Multi-Mode Microplate Reader.

    Forskolin dose response in HEK293 cells

Technology of CatchPoint cAMP Fluorescent Assay Kit

  • CatchPoint cAMP Assay Principle

    CatchPoint cAMP Assay Principle

    The cAMP in the sample or standard competes with horseradish peroxidase (HRP)-labeled cAMP conjugate for binding sites on the anti-cAMP antibodies. In the absence of cAMP, most of the HRP-cAMP conjugate is bound to the antibody. Increasing concentrations of cAMP competitively decrease the amount of bound conjugate, thus decreasing measured HRP activity.

Ordering Options of CatchPoint cAMP Fluorescent Assay Kit

CatchPoint cAMP Fluorescent Assay Kit

Explorer Kit (96-Wells) - PN: R8088

  • Two (2) 96-well black well/ clear bottom plates
  • 100 mL ELISA Assay Buffer
  • 1 vial Rabbit Anti-cAMP Antibody
  • 1 vial cAMP Calibrator
  • 1 vial HRP-cAMP Conjugate
  • 100mL, 10X Wash Solution Concentrate
  • 50 mL Cell Lysis Buffer
  • 1 vial 100X Substrate
  • 100 mL Substrate Buffer

#R8088

$2,326.00 USD

1

Bulk Kit (96-Wells) - PN: R8089

  • Ten (10) 96-well black well/ clear bottom plates
  • 950 mL ELISA Assay Buffer
  • 2 vials Rabbit Anti-cAMP Antibody
  • 2 vials cAMP Calibrator
  • 2 vials HRP-cAMP Conjugate
  • 950mL, 10X Wash Solution Concentrate
  • 450 mL Cell Lysis Buffer
  • 2 x 900 µL 100X Substrate
  • 950 mL Substrate Buffer

#R8089

$4,043.00 USD

1

Explorer Kit (384-Wells) - PN: R8044

  • Two (2) 384-well black well/ clear bottom plates
  • 100 mL ELISA Assay Buffer
  • 2 vials Rabbit Anti-cAMP Antibody
  • 2 vials cAMP Calibrator
  • 2 vials HRP-cAMP Conjugate
  • 100mL, 10X Wash Solution Concentrate
  • 25 mL Cell Lysis Buffer
  • 1 vial 100X Substrate
  • 100 mL Substrate Buffer

#R8044

$2,571.00 USD

1

Resources of CatchPoint cAMP Fluorescent Assay Kit

Compatible Products & Services of CatchPoint cAMP Fluorescent Assay Kit