Electrophysiology
Automated Electrophysiology
Our versatile automated electrophysiology systems are used for primary and
secondary screening and are capable of sophisticated research protocols as well.
New SBS Journal Article on Population Patch Clamp
Conventional Electrophysiology
Automated Electrophysiology
Also see the Automated Electrophysiology comparison chart in the right menu.
IonWorks Quattro
The IonWorks Quattro workstation with Population Patch Clamp
technology, is a turnkey automated patch-clamp system for primary screening of directed compound libraries, secondary
screening of hits from high throughput screening assays, and early safety pharmacology profiling.
PatchXpress 7000A
The PatchXpress 7000A workstation is an automated, flexible,
research grade electrophysiology workstation. Ion channel activity is recorded directly using gigaseal and true
whole-cell recording from up to 16 cells simultaneously. The system supports sophisticated stimulation and
recording protocols, enabling the study of a wide variety of voltage-gated and ligand-gated ion channels.
OpusXpress 6000A
The OpusXpress 6000A workstation is an automated eight channel
voltage-clamp screening system for oocytes. Impalement, fluid delivery, data recording, and real-time analysis are all
performed automatically under computer control on all eight oocytes in parallel. The design of the OpusXpress 6000A
system ensures excellent voltage control and recordings with high bandwidth.
Conventional Electrophysiology |
 |
Microelectrode Amplifiers

Also see the Microelectrode Amplifiers comparison chart in the right menu.
Axoclamp 900A is a computer-controlled microelectrode current-clamp
and voltage-clamp amplifier, useful for a wide range of intracellular microelectrode recording techniques with
several modes of operation: two independent current clamp amplifiers with bridge balance, two-electrode voltage
clamp, discontinuous current clamp, discontinuous single-electrode voltage clamp, and high-voltage current clamp.
MultiClamp 700B is a computer-controlled microelectrode
amplifier with a high-speed current clamp capable of sharp-electrode, field potential or ion-selective
measurements, and a patch clamp for whole-cell, excised or cell-attached patches, bilayers, and
electrochemistry with voltammetry or amperometry.
Axopatch 200B is the premier patch-clamp
amplifier for all patch-clamp configurations, with capacitive-feedback and cooling in the headstage for
ultra-low noise single-channel recordings.
Find accessories in Headstages and Holders
and Model Cells, Cables, Odd Bits.
Data Acquisition Systems

Digidata 1440A is a low-noise digitizer for recording data
onto a Windows computer. Digidata 1440A is compatible with pCLAMP 10.
Electroporation

Axoporator 800A is the world's first commercially
available micropipette-based system for single-cell electroporation.
|