Molecular Devices Home
Careers  |  Contact Us  |  Search:   

  

MultiClamp Commander for Windows History

MultiClamp 700B Commander

Version 2.1.0.09   (16 January 2006)

Changes:

  • The voltage meter now reports zero mV when auto pipette offset is applied.

Version 2.1.0.08   (6 January 2006)

Changes:

  • Voltage meter now reports correct polarity when meter adjusted for pipette offset in current clamp.
  • Fixed auto bridge balance API command and added bridge balance examples to MCCMSG_TestBed.
  • Removed static text "No MultiClamp connected" from device dialog.
  • Updated copyright information.

Version 2.1.0.07   (1 April 2005)

Changes:

  • Fixed XP error when application closed.
  • Shortened dialog title from "MultiClamp 700B: Serial Number 01234567" to "MultiClamp 700B: ( 01234567 )" to fit at higher screen resolutions on XP.

Version 2.1.0.05   (16 March 2005)

Changes:

  • Fixed DLL errors related to Slow Current Injection parameter and Primary / Secondary Scaled Output signals (i.e., 3rd party communication improvements).

Version 2.1.0.04   (28 September 2004)

Changes:

  • Meters are now correctly updated when Auto Pipette Offset is selected while Seal Test/Tuning signal is enabled. Test signals are now disabled during the automatic offset.

Version 2.1.0.02   (12 July 2004)

Changes:

  • Fixed IC gain not applied on channel after auto PO.
  • Fixed test signal frequency not restored correctly.
  • Added command line switch to replace the dialog title.
  • Bumped minor version to 2.1 for AxMultiClampMsg DLL support.
  • Created Start menu subfolder "3rd Party Support", included source code and links to PDF files.
  • AxMultiClampMsg now supports all MCC commands within the voltage and current clamp tabs. Commands in Options tabs are not supported.
  • Added 3rd party support files to installer.
  • Added start menu link and help page about 3rd party support files.
  • Disable automatic gain reversion when Output Zero disabled.
  • Added support for AxMultiClampMsg, a DLL that allows control of the Commander from 3rd party applications.
  • Added automatic meter ranging. This prevents meter overloads by dynamically extending the measurement range from ±2.50 to ±25.0 V.
  • Fixed gain range display in Gain tab.

Version 2.0.0.27   (23 January 2004)

Changes:

  • Improved Tool Tips for primary and secondary output signals.
  • Added missing help pages for "slow current injection" and "connecting to the MultiClamp."
  • Fixed minor details on various help pages.
  • Changed "MultiClamp xxxxxxxx currently open" to "MultiClamp xxxxxxxx connected" in Select Device dialog.

Version 2.0.0.26   (19 December 2003)

First download version.

MultiClamp 700A Commander

Version 1.3.0.05   (16 January 2006)

Changes:

  • Fixed auto bridge balance API command and added bridge balance examples to MCCMSG_TestBed.
  • Updated copyright information.

Version 1.3.0.04   (16 March 2005)

Changes:

  • Fixed DLL errors related to Slow Current Injection parameter and Primary / Secondary Scaled Output signals (i.e., 3rd party communication improvements).

Version 1.3.0.03   (28 September 2004)

Changes:

  • Meters are now correctly updated when Auto Pipette Offset is selected while Seal Test/Tuning signal is enabled. Test signals are now disabled during the automatic offset.

Version 1.3.0.02   (12 July 2004)

Changes:

  • Fixed IC gain not applied on channel after auto PO.
  • Fixed test signal frequency not restored correctly.
  • Bumped minor version to 1.3 for AxMultiClampMsg DLL support.
  • Created Start menu subfolder "3rd Party Support", included source code and links to PDF files.
  • Added automatic meter ranging. This prevents meter overloads by dynamically extending the measurement range from ±2.50 to ±25.0 V.
  • AxMultiClampMsg now supports all MCC commands within the voltage and current clamp tabs. Commands in Options tabs are not supported.
  • Added 3rd party support files to installer.
  • Added start menu link and help page about 3rd party support files.
  • Disable automatic gain reversion when Output Zero disabled.
  • Added support for AxMultiClampMsg, a DLL that allows control of the Commander from 3rd party applications.

Version 1.2.0.00   (8 March 2004)

Changes:

  • The install folder, directory, registry, desk top icon, splash screen, about dialog and help file references have been changed to "MultiClamp 700A Commander."
  • Decreased default Rs Compensation bandwidth to 1 kHz (was 4 kHz).
  • Prevent reset of dialog position and size on "Reset to Program Defaults."
  • Fixed bug where Auto Pipette Offset activated Holding field.

Version 1.1.2.27   (9 September 2003)

Changes:

  • Set the default Rs Compensation bandwidth to 4 kHz (was 16.24 kHz).
  • Meter display corrected for Bridge Balance or Leak Subtraction.

Version 1.1.2.26   (28 July 2003)

Changes:

  • Fixed problem where the Commander sometimes lost communication with the SoftPanel.

Version 1.1.2.25   (7 May 2003)

Changes:

  • Increased pipette offset glider range from ±5 mV to ±100 mV.

Version 1.1.2.24   (4 February 2003)

Changes:

  • Installs on Windows XP and ME.
  • Installs directly over previous versions.
  • Unlock Pipette Offset mapped to SoftPanel.
  • Quick Select (buttons 1, 2, 3) mapped to SoftPanel.
  • SoftPanel Quick Select will launch external program if path is not *.mcc.
  • Commander screen position is maintained upon exit.

Version 1.1.2.20   (4 October 2002)

Changes:

  • Now correctly identifies an HS-2A (any sub-type) headstage connected to the "Bath Headstage" input on the rear panel, and will list "Bath Potential 1 V/V" as a Scaled Output signal.

Version 1.1.2.19   (12 June 2002)

NOTE:  This new version of Commander software has Scaled Output selections that differ slightly from previous versions! Users will now see:

  1. Pipette Potential (Pipette Offset value included).
  2. Membrane Potential (Pipette Offset value subtracted).
  3. 100xAC Pipette Potential.

Other changes:

  • Extended Whole Cell cap. comp. range to ~275pF.
  • Fixed voltage meter display to reflect IC pipette offset glider changes.
  • Added Raw Output to telegraph data packet.
  • Updated SDK reference document.

Version 1.1.2.12   (28 November 2001)

Changes since the original release:

  • Added <Shift>, <Ctrl>, <Home>, and <End> keys to the SoftPanel button list for glider acceleration.
  • Added Window Minimize and Window Restore to SoftPanel button list.
  • Added Headstage Matching/Tuning dialog in Advanced Options page.
  • Added Manual Pipette Offset adjustment glider.
  • Added SoftPanel support.
  • Added Update Reminder dialog.
  • Updated Online Help.

Version 1.1.2.10   (26 September 2001)

Version 1.1.2.5   (26 June 2001)

Version 1.1.2.1   (4 June 2001)

Version 1.0.1.47   (29 January 2001)

Version 1.0.1.42   (Initial release, shipped on the Version 1.0 CD)