Model Cells, Cables, Odd Bits |
 |
Model Cells and Adapters

Click on the pictures to see the model cell circuit diagrams
CLAMP-1U model cell
Suitable for evaluating two-electrode voltage clamp and discontinuous
single-electrode voltage clamp. Contains two "electrodes" that can
be connected to the "bath" or the "cell." Connectors are
suitable for U-type HS series headstages. Provided at no charge with all
Axoclamps and Axoprobes.
|
 |
PATCH-1U model cell
Simulates whole-cell clamp and single-channel patch-clamp conditions. Connectors
are suitable for U-type CV series headstages. Provided at no charge with all Axopatches.
|
 |
MCO-2U oocyte model cell
Simulates the membrane resistance, membrane capacitance and a membrane- bound component of the series
resistance. Resistors simulate the intracellular electrodes, a patch-clamp electrode and the bath
grounding and sensing electrodes. A switch enables testing the amplifier under conditions of high
current/low membrane resistance. Connectors are suitable for U-type HS series headstages.
|
 |
MCB-1U bilayer model cell
Contains a series resistor and capacitor to simulate a bilayer membrane.
Connectors are suitable for U-type CV series headstages. The MCB-1U is provided
with the Axopatch 200A patch clamp.
|
 |
MCW-1U whole-cell model cell
Simulates a whole-cell patch-clamp recording system. Connectors are suitable
for U-type HS series headstages. Provided at no charge with the Axoclamp-2B.
|
 |
Model Cell Adapters
HS and CV headstages are connected to model cells through 1 or 2 mm pin connectors.
We supply adapters on request that facilitate connections between headstages and model
cells of different types. All adapters have a socket on one end and a pin on the other
end. Adapter descriptions and Axon Part Numbers (APN #) are given in the table below.
| Model Cells | Headstages |
HS non-U type 2 mm socket | CV non-U type 1 mm socket | HS & CV U type 1 mm socket |
Non-U type 2 mm pins Clamp-1 MCB-1 MCO-1 E1,E2* MCW-1 | No adapter needed | 2 mm socket to 1 mm pin APN 2200-063 | 2 mm socket to 1 mm pin APN 2200-063 |
Non-U type recessed 1 mm pins MCO-1 E3* Patch-1 | 1 mm socket to 2 mm pin APN 2200-083 | 1 mm socket to 1 mm pin APN 2200-062 | 1 mm socket to 1 mm pin APN 2200-062 |
U type 1 mm pins Clamp-1U MCB-1U MCO-1U E1,E2,E3* MCW-1U Patch-1U | 1 mm socket to 2 mm pin APN 2200-083 | 1 mm socket to 1 mm pin APN 2200-062 | No adapter needed |
*E# - electrode input #
All ground connections on model cells and headstages have 2 mm sockets, except the
CV203BU headstage, which has a 1 mm ground socket.
Cables

USB-Serial Converter PC serial adapter
Adds a serial port to PC computers with only USB ports. Allows use of the
APN 2100-0623 PC serial cable for computer-controlled amplifiers. For use
with MultiClamp 700A, GeneClamp 500B, and CyberAmp 380/320.
APN 2100-0623 PC serial cable
25-to-9 pin serial cable connects PC computers to computer-controlled amplifiers
(MultiClamp 700A, GeneClamp 500B and CyberAmp 380/320). This null-modem cable
requires a 9-pin serial port connector on the computer.
APN 2100-0134 expansion cable
Links computer-controlled amplifiers together, to allow them to run from a single
serial port. Two-foot long "straight-through" flat ribbon cable.
APN 2100-0165 Macintosh serial cable
Connects Macintosh computers to computer-controlled amplifiers (GeneClamp and CyberAmp.)
This null-modem cable requires a Macintosh-style serial port connector on the computer.
 |
LU-1 link-up cable
Allows the sample rates of two Axoclamps to be synchronized.
|
Odd Bits

 |
HLP-0 pack of 5 general-purpose 2 mm plugs
2 mm plugs are used with the grounding jack of all headstages. These plugs also
fit the input of non-U-type HS, VG and BH series headstages, and many SmartProbes.
|
RD-1-n headstage mounting rods
4 inch (100 mm) long insulated rods screw into back of all headstages.
Replace "n" with diameter 1/4, 5/16 or 3/8 inch (6.3, 7.9 or 9.5 mm).
RD-1-5/16 is supplied standard with all headstages.
|
 |
 |
Buzz Duration Control
Hand-held control to enable the Buzz duration on the Axoclamp to be controlled
in the range 1-50 ms. Provided at no charge with all Axoclamps.
|
Capacitance Measurement

DR-1 series resistance dither unit
Normally provides a short-circuit link between the preparation and ground.
Under control of an external TTL-level signal, the DR-1 inserts a
500 kΩ resistor in series with the bath ground.
The DR-1 is suitable for finding the phase tracking angle in capacitance
measurement experiments using an Axopatch 200B amplifier.
|